SCOPE AND APPLICATION
This method is used to determine the presence of free liquids in a representative sample of waste.
The method is used to determine compliance with 40 CFR 264.314 and 265.314.
SUMMARY OF METHOD
A predetermined amount of material is placed in a paint filter. If any portion of the material passes through and drops from the filter within the 5-min test period, the material is deemed to contain free liquids.